PANTHER HAMMERS
GENERAL CARE
Before shutting down at the end of each shift, we recommend the following procedures :
- Flush Hammer with air/ water for a few minutes, then turn off water injection.
- Flush Hammer with air/oil for a few minutes. This will coat the internal Hammer parts preventing corrosion / rust.
- Never leave the tool in a wet/ muddy hole. Pull back from bottom as far as necessary to prevent the Hammer sitting under water.
- It is also good practice to pour at least half a litre of oil down the drill at start up of a new shift.
- If the Hammer is removed from the drill rig for any reason, it is wise to pour a quantity of oil into it and block both ends, providing the flushing as outlined in steps one and two above have been carried out. If steps one and two have not been carried out the Hammer should be stripped, cleaned and oiled before being stored.
| # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 |
Component Name Piston Case/ Std Barrel Std Piston Std Std Seat Valve Std Std Chest Valve Std Liner Top Sub / Std Back Head Driver Sub/ Std Front Chuck Std Flapper Valve Std Valve Guide Guide Sleeve/ Std Assembly Bush Bit Retainer Ring/ Std Bit Lock Dart / Std Check Valve Std Check Valve Cap Retainer Pin/ Std Dowell Pin Std Spring Std Washer Std Stem Bush O Ring/ Std Bit Lock O Ring Std Blocking Choke Std Front Chuck Rubber Cap Std Back Head Rubber Cap |
H45P HB45P HP45P HSV45P HCV45P HL45P HC45P HFC45P HFV45P HVG45P HAB45P HBL45P HCKV45P HCVC45P HDP45P HS45P HMW45P HSB45P HBR45P HBC45P HFCRC45P HCRC45P |
H45PLT HB45PLTLT HP45PLT HSV45PLTLT HCV45PLTLT HL45PLT HC45PLT HFC45PLT HFV45PLT HVG45PLT HAB45PLT HBL45PLT HCKV45PLT HCVC45PLT HDP45PLT HS45PLT HMW45PLT HSB45PLT HBR45PLT HBC45PLT HFCRC45PLT HCRC45PLT |
H45PS HB45PS HP45PS HSV45PS HCV45PS HL45PS HC45PS HFC45PS HFV45PS HVG45PS HAB45PS HBL45PS HCKVC45PS HCVC45PS HDP45PS HS45PS HMW45PS HSB45PS HBR45PS HBC45PS HFCRC45PS HCRC45PS |
| # | Hammer Name | Part Number | Outside Dia (mm) | Recomm Bit size (mm) | Top Sub Thread (IN) | Ham. Wt. Without Bit (kg.) | Total Len without Bit (mm) | Wrench Flat (mm) | Working Pressure (Bar) |
| 1 | P45 Hammer | H45P | 96.00 | 114.30 - 130.00 | 2-3/8 Reg box | 42.00 | 994.0 | 74.0 | 7.5 - 14.5 |
| 2 | P45 LT Hammer | H45PLT | 96.00 | 114.30 - 130.00 | 2-3/8 Reg box | 44.00 | 1070.0 | 74.0 | 7.5 - 14.5 |
| 3 | P45 Sup. Hammer | H45PS | 96.00 | 114.30 - 130.00 | 2-3/8 Reg box | 43.50 | 1044.0 | 74.0 | 7.5 - 14.5 |
- For use in hard rock application
- Suitable for Horizontal & Vertical drilling Operations
- Excellent under water characteristics
- Able to work on any strata
- Less maintenance